都安瑶族Design and calculation of industrial coolers

都安瑶族

dustrial coolers,design

都安瑶族

:本文围绕工业冷却器的设计与计算展开,阐述了工业冷却器在工业生产中的关键作用,其能有效地降低设备或工艺流程的温度,保障系统稳定运行,详细介绍了设计环节,包括依据不同的工业场景和冷却需求确定冷却器的类型,如风冷式、水冷式等,同时考虑冷却介质的特性、流量等参数,在计算方面,着重讲解了热负荷的计算方法,通过分析被冷却对象的热量产生速率、环境温度等因素,精准计算出所需的换热量,还涉及冷却器传热面积、传热系数等关键参数的计算,以确保冷却器能达到预期的冷却效果。

都安瑶族1、Design basis

都安瑶族

Design Standard for Steel Structures GB50017-2017Steel Structure Design Manual, China Construction Industry Press, January 2004

都安瑶族

Code for Construction and Acceptance of Steel Structures (GB50205-2020)

都安瑶族

British Code for Design of Steel Structures (BS5950)

都安瑶族

都安瑶族2、Design load

Load includes structural self weight, wind turbine constant load, live load, snow load, wind load, etc. The structural calculation adopts the ultimate stress method, therefore, the load value is larger than usual. The surface load is calculated based on the distribution coefficient and applied to the platform according to the line load. The wind load is calculated based on the wind vibration coefficient, body shape coefficient, and basic wind pressure to calculate the wind pressure values on four surfaces, which are then converted into line loads and applied to the columns. Auxiliary components such as stair handrails are applied to the stairs according to uniformly distributed loads.

都安瑶族

都安瑶族1. Constant load

都安瑶族

The self weight of the steel structure is automatically calculated by the program, and the node weight is considered based on the self weight of the structure multiplied by 1.3. The weight and fluid load of the radiator are applied by external forces.

Platform constant load: 0.50kN/m2

都安瑶族

2. Live load

Live load of the platform for loading: 2.5kN/m2

都安瑶族

3. Snow load

都安瑶族

According to relevant design data, the snow pressure can be basically calculated as 0.4N/m2.

都安瑶族

都安瑶族4. Wind load

都安瑶族

都安瑶族Calculate according to the maximum value.

Basic wind pressure: 0.35kN/m2, height variation coefficient of 1.8, wind vibration coefficient: 1.5, ground roughness category: Class A

都安瑶族Class.

都安瑶族

Is the standard value of wind load, is the wind vibration coefficient at height Z, is the shape coefficient of wind load, and is the coefficient of wind pressure height variation.

When the standard value of wind load is less than 0.75kpa, calculate based on 0.75 kPa and multiply by 1.4 times the safety factor. Namely

都安瑶族

5. Temperature load

都安瑶族The temperature difference is relatively small. The structural form is single, and the linear expansion of steel has a relatively small impact on the overall performance of the structure, which can be ignored.

都安瑶族

都安瑶族6 Earthquake loads

都安瑶族

都安瑶族According to the seismic analysis design method: small earthquakes do not damage, medium earthquakes are repairable, and large earthquakes do not collapse. Small earthquake analysis can be divided into: bottom shear force method, response spectrum analysis, and elastic time history analysis. Medium earthquake analysis is calculated by multiplying small earthquake analysis by amplification factor.

都安瑶族Seismic fortification intensity: 8 degrees

都安瑶族Design basic seismic acceleration peak value: 0.3g

都安瑶族Construction site category: II site

Design grouping: Second group

都安瑶族

都安瑶族Damping ratio: 0.05

都安瑶族

都安瑶族This structure adopts MIADS software for overall modeling and analysis. During modeling, beam elements are mainly used for each structure. In order to facilitate loading, plate elements are established at the structural platform. Consolidation is used as the boundary condition at the bottom of each column, and constraints are applied at the connection between the column and the original structure according to the actual situation. The structure includes upright column, cross brace, slant support and upper and lower platform steel structure.

都安瑶族Load sub factors and load combinations:

Number

load

都安瑶族Partial    coefficient remarks

Partial    coefficient remarks

都安瑶族

都安瑶族1

dead load

1.3

都安瑶族2

Dead load, when   it has a restraining effect on uplift and   overturning

都安瑶族

都安瑶族1.0

都安瑶族3

Dead load, when   acting together with wind load and live load

1.2

都安瑶族4

Live load

1.6

都安瑶族

5

都安瑶族

都安瑶族Live load, when   combined with wind load

1.2

都安瑶族

都安瑶族6

都安瑶族

都安瑶族Wind load

1.4

都安瑶族

7

都安瑶族When combined   with wind load and live load

都安瑶族

1.2

都安瑶族

3、 Radiator calculation

都安瑶族1. Material parameters

Aluminum alloy adopts 6005-T1, with tensile strength and yield strength equivalent to 6063-T5, tensile strength ≥ 150Mpa, yield stress ≥ 110 Mpa. According to the performance table of aluminum alloy, it is found that 6063-T5 has a tensile strength of 185Mpa, yield stress of 145 Mpa, and fatigue strength of 90MPa.

2. Working condition analysis

都安瑶族

都安瑶族The calculation of radiators can be divided into 1. lifting ondition,

都安瑶族

都安瑶族3. operating condition (operating condition is divided into

4.support and lifting point participate in force simultaneously.

都安瑶族

5.support bears gravity, while lifting point bears horizontal force.

都安瑶族

都安瑶族6.support does not bear any force, that is, when the overall structure is subjected to uneven settlement, there is a suspension at the bottom)

都安瑶族

To ensure its stability, it is recommended that the foundation treatment should be pre compressed and settlement assessment should be carried out during the overall installation.

都安瑶族

2.1 Hoisting conditions

都安瑶族At this point, the radiator is only considered for its own weight due to the lack of fluid injection, and is lifted and installed through a side lifting point. Because no other accessories were installed during modeling, in order to estimate the weight more accurately, its self weight coefficient was defined as 1.3.

都安瑶族The radiator structure consists of 1, frame 2, support beam 3, heat exchange tube 4, tube plate, and other ancillary structures. As the heat exchange tube and support beam are fixed together through a corrugated plate, it can be considered that the heat exchange tube participates in the structural stress, which leads to strain and stress generation.

都安瑶族

The overall structural model is

都安瑶族

都安瑶族

都安瑶族Radiator structural model

都安瑶族

都安瑶族

The overall deformation of the radiator during the lifting process

都安瑶族

都安瑶族Stress cloud diagram of radiator during lifting process

都安瑶族

From its displacement cloud map, it can be seen that its overall deformation is 1.2mm, and the maximum stress is 15MPa

都安瑶族

都安瑶族Stress cloud map of heat sink

都安瑶族

都安瑶族 

Displacement cloud map of heat sink

都安瑶族

都安瑶族From its displacement cloud map, it can be seen that its overall deformation is 1mm and the maximum stress is 2MPa. Through calculation, it can be seen that horizontal lifting has little effect on the heat dissipation fins, and its deformation and stress are far less than the standard requirements.

都安瑶族

都安瑶族The vertical lifting situation is as follows:

都安瑶族

都安瑶族

都安瑶族Vertical lifting stress cloud map

都安瑶族


都安瑶族

文章版权声明:除非注明,否则均为原创文章,转载或复制请以超链接形式并注明出处。